• Model
  • CT1-201
  • Part No
  • CT1-201
  • Series
  • CT1
  • Horsepower
  • 20.000
  • Rating kW
  • 15.00
  • Capacity kVA
  • 24.40
  • Input Voltage
  • 380 - 480 +/- 10%
  • Input Phase
  • Three
  • Input Current
  • 35.0
  • Output Voltage
  • 400 - 480 +/- 10% (3P)
  • Output Current
  • 32.0000
  • Package Height
  • 13
  • Package Width
  • 11
  • Package Depth
  • 13
  • Package Weight
  • 20.0
  • Product Height
  • 15.4000
  • Product Width
  • 10.3000
  • Product Depth
  • 7.8000
  • Summary
  • CT1-201
  • Description
  • CT1-201
  • Category
  • Drives
  • SubCategory
  • AC Drives
  • SubSubCategory
  • Sensorless Vector VFD
  • Enclosure
  • NEMA 1 (IP20)
  • Control Method
  • Sine-Wave (PWM) control
  • Input Frequency Range
  • 50 - 60
  • Output Frequency Range
  • 0.1 - 600 Hz
  • VF Characteristics
  • Adjustable V/F curve using 4 independent points.
  • Overload Current Rating
  • 150% 60 seconds
  • Accel Decel Time
  • 0.1 ~ 6000 sec. (2 independent settings for Accel/Decel Time)
  • DC Braking
  • DC Braking Current Level: 0 to 125% of rated output current. DC Braking time: 0 to 60 seconds. Start-Point for DC Braking: 0.1-600Hz both when start up and stop.
  • Freq Setting Operator Panel
  • By a rotary encoder (setting resolution 0.01Hz/step)
  • Freq Setting External Signal
  • "0 ~ +10VDC (Input impedance 20k ohms), -10 ~ +10VDC (Input impedance 10k ohms), 4 ~20mA dc (Input impedance 250 ohms), Multi-Function Inputs 1 ~ 6 (15 Steps Jog up/down), PLC run RS-485 Interface MODBUS protocol"
  • FWD REV START STOP Operator
  • "Set by RUN
  • FWD REV START STOP External Signal
  • STOP and JOG"
  • Protective Functions
  • "PID feedback control
  • Enviornment Operating Temperature
  • automatic voltage regulation
  • Enviornment Storage Temperature
  • Momentary Power Loss restart
  • Enviornment Humidity
  • S-Curve
  • Enviornment Vibration
  • External Fault
  • Manufacturer
  • Polyspede
Customers who bought this product also purchased